Brief and design basis
Building use, occupancy, design conditions, the codes the project must meet and the responsibility split — agreed and written down before any calculation is run.
Power and lighting designed from the load assessment up, with distribution, containment and switch rooms sized before they are squeezed into the space that is left.
Electrical design
Connected and maximum demand decide the incoming supply, transformer and switchgear, and therefore the size of the electrical rooms. We establish it first and keep it current as the other disciplines' equipment changes.
Boards, their working space and the containment arriving at them need dimensioned rooms and risers. Designing those in the model avoids the late discovery that the room no longer fits.
Design is carried out by BIMRACE's qualified engineers within the design responsibility written into the appointment. Where a jurisdiction requires a locally licensed engineer to sign, stamp or submit drawings and calculations, that engineer of record does so; we prepare and support the submission. Authority approvals are obtained by the appointed professionals.
Deliverables
Any of these can be appointed on their own or combined. Nothing here depends on buying the intelligence layer, which is not for sale in any case.
Catalogue scope
The full list from the BIMRACE service catalogue. Each item can be included or excluded in a proposal; the code is the one used in our scope documents.
How it runs
Sequence is not a formality on this kind of work. Most of the expensive rework we are asked to fix was produced by doing step four before step two.
Building use, occupancy, design conditions, the codes the project must meet and the responsibility split — agreed and written down before any calculation is run.
System options compared for space, energy, capital and maintenance cost, with plant and riser space reserved early so the architecture can accommodate them.
Loads, flows and sizes calculated to the stated method, with assumptions listed on the calculation rather than buried in it.
The design is drawn directly in Revit, so sizes, routes and equipment data live on the elements and coordination starts from the design, not after it.
Federated clash and clearance checks against architecture, structure and the other services; an independent engineering review before issue.
Design drawings, calculations, schematics and schedules issued under revision control, with support through tender, approvals and construction queries.
What we need to start
Missing any of these is survivable. Not knowing which of them are missing is not, so we establish it at enquiry stage rather than at forty per cent.
AI & automation
AI is used throughout our delivery workflow, and an engineer reviews every output. Every line carries its real status.
Scope boundary
Published because a scope boundary discovered at month three is a dispute, and the same boundary stated at enquiry stage is just information.
Request a quote
Tell us the building, the stage and what you need. An engineer replies within two working days with approach, deliverables and a fee basis.
Quote request received
Have drawings ready? Use the full enquiry form to attach them.
What a useful quote needs. Building type and approximate area, the disciplines, the project stage, and which drawings or models exist. If you have them ready, the full enquiry form takes file uploads.
NDAs. We sign before drawings or models are shared, as a matter of course.
FAQ
Yes — the load assessment, distribution strategy, single-line diagrams and panel schedules are core electrical design deliverables.
Yes, general and emergency lighting layouts to the illuminance and standard the project requires.
The project's — for example IEC 60364, BS 7671, the NEC or India's IS 732 and National Building Code.
Engineering enquiry
Send a scope, a drawing set or the workflow you want this applied to. You will get a technical response on approach, disciplines, deliverables and what is realistically automatable — from an engineer, not a sales desk.